Pressure Vacuum Equipment List
Equipment Type | Range | Accuracy |
Altitude Gauges | -1000 to 100000 ft | Up to 0.2% |
Dead Weight Tester (Hydraulic) | 1 to 10000 psi | Up to 0.01% |
Gram Gauges | Varies | Dependent on Range |
Mercury Manometers | 0 to 2000 in-Hg | Up to 0.02% |
Water Manometers | 0 to 2700 in-H2O | Up to 0.02% |
Pressure Calibrators / Controllers | 0 to 10000 psi | Up to 0.01% |
Absolute Pressure Gauges | 0 to 10000 psia | Up to 0.01% |
Compound Pressure Gauges | -15 to 72500 psi | Up to 0.02% |
Differential Pressure Gauges | 0 to 10000 psid | Up to 0.02% |
Magnahelic Pressure Gauges | 0 to 2700 in-H2O | Up to 0.05% |
Pressure Gauges | 0 to 72500 psi | Up to 0.01% |
Absolute Pressure Transducer | 0 to 10000 psi | Up to 0.01% |
Pressure Transducers | 0 to 72500 PSI | Up to 0.01% |
Differential Pressure Transmitter | 0 to 72500 PSI | Up to 0.01% |
Pressure Transmitters | 0 to 72500 PSI | Up to 0.01% |
* If not on the list, please inquire *
Capabilities: Vacuum Gauge Calibration
Operating range 1X10-13th
Equipment Type | Range | Accuracy |
Hi Vacuum Gauges | 1x10-13 | Varies |
Vacuum Gauges | 0 to -30 inHg | Up to 0.01% |
Vacuum Transducers | 0 to -30 inHg | Up to 0.01% |
* If not on the list, please inquire *
Why Choose Micro Quality Calibration, Inc.?
The Best Kept Secret In Metrology-
Accredited to the Highest Standard
We are fully accredited to A2LA ISO/IEC 17025, meeting the requirements of ANSI/NCSL Z540.3-2006 and ANSI/NCSL Z540-1-1994, traceable to N.I.S.T. and compliant to the 9000 Series.
-
History of Success
Founded in 1978, Micro Quality Calibration continues to grow and is now serving more than
2,000 customers. -
Nationwide Service
We are the metrology company of choice to thousands of customers in Southern California & across the country.
-
Proprietary Calibration Software
Our customers have 24/7 access to certificates, recall reports, equipment lists, & real-time equipment tracking within our facility.
-
Broad Capability & Service Offering
We do not sub-contract our work and have the ability to calibrate Primary, Secondary & Working standards in each of our disciplines.
-
Unrivaled Turnaround Time
We have a 5-Business-Day turnaround time, with expedite options available 24 hr, 48 hr, and 72 hr.
-
State-of-the-Art Laboratory
22,000 square foot, seven-laboratory, environmentally-controlled facility.
-
Ability to Repair Any Instrument We Calibrate
We can repair down to the component level and certify to Manufacturer, Federal, Military & Industrial specifications.
We specialize in calibration, repair, testing and First Article Inspection in several major industries. Get in touch with us today.