mobile calibration

Mobile Calibration




Contact Us:
(818) 701-4969

Micro Quality Calibration (MQC) is at the forefront of the Metrology industry with a service offering and mobile calibration capabilities unmatched among its peers. Our A2LA ISO/IEC 17025-2005 accreditation mandates us to uphold the highest level of quality assurance, documentation, and accuracy. You can rest assured that your equipment will be serviced to the highest quality disciplines while our staff provides exceptional service, keeping you updated on the statuses of your assets.

Do you need immediate service? Are your environmental conditions suboptimal? Do you want to minimize disruptions on the production floor and reduce turnaround time?  MQC’s Mobile Calibration Laboratory is your answer.

Whether in-house, on-site, or mobile, our focus on providing high quality work, timely execution, exceptional customer service, need flexibility, and complete repeatability remains the same. We continue to invest in state-of-the-art test equipment with the sole purpose of providing our customers the ability to solve their most intricate measurement needs at the highest accuracy with our complete suite of services. MQC continues to push and strive to extend its service offering and expand its capabilities. Our Mobile Calibration Laboratory can perform A2LA ISO 17025 accredited calibrations and much more.

 

Capabilities include (see scope of accreditation for full capabilities and ranges):

Mobile Calibration Capabilities

 

Scope Parameter / Equipment Range
     
Chemical pH Measuring Equipment 4.01 pH, 7.00 pH & 10.00 pH
Chemical Conductivity Measuring Equipment 100 µS, 1412 µS & 10 004 µS
Dimensional Equipment Micrometers Up to 12 in
Dimensional Equipment Calipers Up to 20 in
Dimensional Equipment Indicators Up to 4 in
Dimensional Equipment Height Gauges Up to 40 in
Dimensional Equipment Microscopes Up to 8 in
Dimensional Equipment Surface Plate Flatness 36 in × 72 in
Dimensional Equipment Optical Comparators X Axis Up to 8 in & Y Axis Up to 4in
DC/Low Frequency DC Voltage - Generate Up to 220 mV,  220 mV to 2.2 V,  (2.2 to 11) V,  (11 to 22) V,  (22 to 220) V,  (220 to 1100) V
DC/Low Frequency DC Voltage - Measure Up to 100 mV , (0.1 to 1) V , (1 to 10) V , (10 to 100) V , (100 to 1000) V,
DC/Low Frequency DC Current - Generate Up to 220 μA , 220 μA to 2.2 mA , (2.2 to 22) mA , (22 to 220) mA , 220 mA to 2.2 A
DC/Low Frequency DC Current - Measure Up to 100 nA , 100 nA to 1 µA , (1 to 10) µA , (10 to 100) µA , 100 µA to 1 mA , (1 to 10) mA , (10 to 100) mA , 100 mA to 1A
DC/Low Frequency Resistance - Generate Fixed Points (1, 1.9) Ω, (10, 19) Ω, (100, 190) Ω, (1, 1.9) kΩ, (10, 19) kΩ, (100, 190) kΩ, (1, 1.9) MΩ, 10 MΩ, 19 MΩ, 100 MΩ
DC/Low Frequency Resistance - Measure (0 to 10) Ω, (10 to 100) Ω, 100  to 1 kΩ, (1 to 10) kΩ, (10 to 100) kΩ, (0.1 to 1) MΩ, (1 to 10) MΩ, (10 to 100) MΩ
DC/Low Frequency Electrical Simulation of Thermocouple Type J, Type K and Type T
DC/Low Frequency Capacitance - Generate (10 to 1000) Hz , (10 to 600) Hz , (10 to 300) Hz , (10 to 150) Hz , (10 to 120) Hz , (10 to 80) Hz , DC to 50 Hz , DC to 20 Hz - See scope for frequency
DC/Low Frequency AC Voltage - Generate Up to 2.2 mV, (2.2 to 22) mV, (22 to 220) mV, 220 mV to 2.2 V, (2.2 to 22) V, (22 to 220) V - See scope for frequency
DC/Low Frequency AC Voltage - Measure Up to 10 mV, (10 to 100) mV, 100 mV to 1 V, (1 to 10) V, (10 to 100) V, & (100 to 1000) V - See scope for frequency
DC/Low Frequency AC Current - Generate Up to 220 μA, 220 µA to 2.2 mA, (2.2 to 22) mA, (22 to 220) mA, 220 mA to 2.2 A - See scope for frequency
DC/Low Frequency AC Current - Measure  to 100 μA , 100 μA to 1 mA , (1 to 10) mA , (10 to 100) mA , 100 mA to 1 A  - See scope for frequency
DC/Low Frequency Oscilloscopes Amplitude DC Signal, Rise Time, Leveled Sine Wave, Flatness, Time Marker   - See scope for frequency
Electrical - RF / Microwave Amplitude Modulation Carrier: (0.15 to 10) MHz & Carrier: 10 MHz to 1.3 GHz - Depth: Up to 99 % - See scope for frequency
Electrical - RF / Microwave Frequency Modulation Carrier: 250 kHz to 10 MHz & Carrier: 10 MHz to 1.3 GHz - Dev: Up to 40 kHz & Dev: Up to 400 kHz, Respectively - See scope for frequency
Electrical - RF / Microwave Phase Modulation Carrier: 150 kHz to 10 MHz & Carrier: 10 MHz to 1.3 GHz
Electrical - RF / Microwave Relative Power - Measure (0 to -10) dBm , (-10 to -20) dBm , (-20 to -30) dBm , (-30 to -40) dBm , (-40 to -50) dBm , (-50 to -60) dBm, -60 to -70) dBm , (-70 to -80) dBm , (-80 to -90) dBm , (-90 to -100) dBm - 10 MHz to 26.5 GHz
Fluid Quantities Flow - Nitrogen Gas (0.05 to 0.5) lpm , (0.5 to 5) lpm , (3 to 30) lpm , (10 to 100) lpm , (10 to 500) lpm
Mechanical Pressure Gauge (725 to 72 500) psi
Mechanical Transducer (1 to 10 000) psi
Mechanical Vacuum -15 to 1000) psia
Mechanical Torque Analyzers (25-250) ft·lbf, (80 to 1000) in·lbf , (0 to 50) in·lbf
Mechanical Torque Wrenches 4 in·lb to 2000 ft·lb
Mechanical Force Gauge (1 to 100) lbf , (5000 to 60 000) lbf, (350 to 30000) lbf , (1 to 1000) lbf
Mechanical Scales & Balances (0 to 310) g , (0 to 4100) g , (0 to 1000) lb, (0 to 100) lb , (0 to 15) kg
Mechanical Indirect Verification-Rockwell Hardness Testers HRA , HRBW , HRC , HR15N , HR15TW , HR30N , HR30TW , HR45N , HR45TW , HREW  - See scope for range
Thermodynamics Pyrometers (50 to 500) ºC  & (500 to 1200) ºC
Thermodynamics Relative Humidity (10 to 50) ºC  -- (5 to 95) % RH

Preparation

Our Electrical Calibration Laboratory not only uses the most state-of-the-art equipment, but also is environmentally controlled to give the lowest degree of measurement uncertainty. Both temperature and humidity are closely monitored and held to 70°F, with relative humidity not exceeding 40%.

The preparation of your precision measurement test equipment is just as important as the calibration. Preparation varies and is equipment specific. Whether you’re seeking calibration of a pyrometer, force gauge, pressure gauge, or any other precision measurement instruments, MQC has the ability to properly handle and service your equipment.

 

Certification

Each calibration / repair / new equipment sale / used equipment sale comes with certificate traceable to N.I.S.T and includes:

  • Barcode & Instrument I.D.
  • Full Data (Before / After) Calibration and/or Repair
  • Condition Received / Condition Returned / Reason for Service
  • Description of Item including Model & Serial Number
  • Measuring Range
  • Procedure Used
  • Calibrating Technician 
  • Temperature & Humidity
  • Accuracy
  • Calibration Standards Employed
  • Numbers Traceable to N.I.S.T.
  • Dual Signatures (Technician and Approval Signature)
  • Certificate Number
  • Purchase Order
  • Calibration Date  / Next Calibration Date
  • Recall / Cycle
  • Repair / Adjustment Note (when applicable)
  • A2LA Accreditation Logo (upon request)
  • Uncertainty (upon request)

Whether you have Primary Standards, Secondary Standards or Working Standards, MQC is one of the few metrology laboratories that has the ability to calibrate your precision measurement test equipment in every service line discipline. Turnaround time is just five business days, with expedite service available.

 

On-site Electrical Calibration Services Available

  • Minimal down time lets you focus on maximizing value
  • Convenient
  • Not necessary to ship delicate and costly instruments
  • Increase productivity
  • Expedite on-site service available

 

Proprietary Calibration Software Gives our Customers 24/7 Access

  • 24/7 Access to Certificates
  • 24/7 Access to Equipment Lists
  • 24/7 Access to Recall Reports
  • 24/7 Access to Calibration Data on your Equipment

MQC not only help its customers create an accurate and comprehensive recall list, but also notifies customers monthly about equipment past due, equipment due in the next 30 days, and equipment due the following month. We supply you with the information you need to better manage your precision measurement test equipment, ensure 100% conformity, and minimize costly downtime. All of this information is also readily available online by simply accessing our web portal, and entering your customer number and password.

 

Why Micro Quality Calibration?

  • Accredited to the highest standards
  • Leading State-of-the-art equipment
  • Environmentally-controlled multi-laboratory facility
  • In-house and onsite calibration services available
  • Proprietary calibration software gives customers 24/7 access to certificates, equipment lists, recall reports, calibration data, and more
  • Each calibration / repair comes with certificate traceable to N.I.S.T, calibration data, standards used, and barcode for inventory tracking
  • Ability to repair any instrument we calibrate to the component level and certify to Manufacturer, Federal, Military and Industrial specifications
  • No subcontracting to 3rd parties
  • Original Equipment Manufacturer (OEM) Trained Technicians
  • Fast 5 business day turnaround time (expedite services available)
  • Free regional pick-up and delivery with shipments of seven (7) items or more
  • Rest assured your valuable precision measurement test equipment will be packaged, picked-up, delivered, and shipped with care
  • Global shipping
  • Sales of over 160 lines of new / used precision measurement equipment (sale items are calibrated at no charge) 
  • Ability to calibrate Primary, Secondary and Working Standards in each category
  • Technical Support Available
  • Women-Owned Small Business (matches both Federal and by State Guidelines)

 

When Quality and Precision Matter, We are the Only Choice

We represent over 160 lines of precision measurement equipment. Below is a listing of just some of the precision measurement equipment lines we represent and/or service. For a full listing, click here.

To learn more about our mobile calibration, electrical calibration, and other precision measurement equipment calibration services, contact us online or call us at (818) 701-4969 today.

 

 

 

 
9168 De Soto Avenue
Chatsworth, CA 91311 USA
Tel: (818)701-4969
Fax: (818)818-6285
 
© 2003-2017 Micro Quality Calibration